With Clickhouse you can use a "buffer table", which uses just RAM and sits on top of a normal table: https://clickhouse.com/docs/en/engines/table-engines/special...

Rows inserted into the buffer table are then flushed to the normal/base table when one of the limits (defined when the buffer table is created) is reached (limits are max rows, max bytes, max time since the last flush), or when you drop the buffer table.

I'm using it and it works (performance difference can be huge compared to perform single inserts directly into a real/normal table), but be careful - the flushed rows don't give a guarantee of which row is flushed in which sequence, so using a buffer table is a very bad idea if your base table is something which relies on the correct sequences of rows that it receives.